Opened 14 months ago

Last modified 14 months ago

#1485 new defect

web-gui alert light/message does not synchronize fast enough with state of system

Reported by: tamada Owned by:
Priority: minor Milestone:
Component: Backend Version: 8.2.0-BETA3
Keywords: Cc:

Description

On a freshly installed FreeNAS-8.2.0-BETA3-x64 (vmware workstation, 6Gig RAM, 4 disks in a RaidZ1) if one simulates the failure of a disk like following:

  1. hard power off freenas (not shutdown)
  2. delte one disk (after power failure one disk broke)
  3. power back on (good: web-gui alert shows message of Raid being degraded)
  4. shutdown freenas
  5. add new disk (replacing old disk)
  6. power on freenas
  7. on "volume status" tab
  • replace removed disk with new one
  • detach removed disk
  1. reload storage tab (no indication of raid being rebuild or anything!)
  2. after some waiting reloaded storage tab reports raid being healty but the web-gui alert light is still on and message unchanged (see attached screenshot)
  3. after a lot more waiting web-gui alert light also changes back to green

For unexperienced users it is very confusing to not get a status update after replacing the disk (such as raid is being rebuilt). If zfs does not deliver this a hint in the web-gui would be good.
Even more confusing is the web-gui alert light/message not changing as soon as the raid is rebuilt.

Attachments (1)

freenas-system-alert.jpg (55.6 KB) - added by tamada 14 months ago.

Download all attachments as: .zip

Change History (2)

Changed 14 months ago by tamada

comment:1 Changed 14 months ago by tamada

  • Version changed from 8.0.2-RELEASE to 8.2.0-BETA3